0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Validity and reliability of a wearable insole pressure system for measuring gait parameters to identify safety hazards in construction

Autor(en):





Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Engineering, Construction and Architectural Management, , n. 6, v. 28
Seite(n): 1761-1779
DOI: 10.1108/ecam-05-2020-0330
Abstrakt:

Purpose

Construction workers are frequently exposed to safety hazards on sites. Wearable sensing systems (e.g. wearable inertial measurement units (WIMUs), wearable insole pressure system (WIPS)) have been used to collect workers' gait patterns for distinguishing safety hazards. However, the performance of measuring WIPS-based gait parameters for identifying safety hazards as compared to a reference system (i.e. WIMUs) has not been studied. Therefore, this study examined the validity and reliability of measuring WIPS-based gait parameters as compared to WIMU-based gait parameters for distinguishing safety hazards in construction.

Design/methodology/approach

Five fall-risk events were conducted in a laboratory setting, and the performance of the proposed approach was assessed by calculating the mean difference (MD), mean absolute error (MAE), mean absolute percentage error (MAPE), root mean square error (RMSE) and intraclass correlation coefficient (ICC) of five gait parameters.

Findings

Comparable results of MD, MAE, MAPE and RMSE were found between WIPS-based gait parameters and the reference system. Furthermore, all measured gait parameters had validity (ICC = 0.751) and test-retest reliability (ICC = 0.910) closer to 1, indicating a good performance of measuring WIPS-based gait parameters for distinguishing safety hazards.

Research limitations/implications

Overall, this study supports the relevance of developing a WIPS as a noninvasive wearable sensing system for identifying safety hazards on construction sites, thus highlighting the usefulness of its applications for construction safety research.

Originality/value

This is the first study to examine the performance of a wearable insole pressure system for identifying safety hazards in construction.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1108/ecam-05-2020-0330.
  • Über diese
    Datenseite
  • Reference-ID
    10577045
  • Veröffentlicht am:
    26.02.2021
  • Geändert am:
    02.09.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine