Towards Seismic Design of Nonstructural Elements: Italian Code-Compliant Acceleration Floor Response Spectra
Autor(en): |
Beatrice Chichino
Simone Peloso Davide Bolognini Claudio Moroni Daniele Perrone Emanuele Brunesi |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Advances in Civil Engineering, Januar 2021, v. 2021 |
Seite(n): | 1-18 |
DOI: | 10.1155/2021/4762110 |
Abstrakt: |
Seismic risk reduction of a building system, meant as primary building structure and nonstructural elements (NSEs) as a whole, must rely upon an adequate design of each of these two items. As far as NSEs are concerned, adequate seismic design means understanding of some basic principles and concepts that involve different actors, such as designers, manufacturers, installers, and directors of works. The current Italian Building Code, referred to as NTC18 hereinafter, defines each set of tasks and responsibilities in a sufficiently detailed manner, rendering now evident that achieving the desired performance level stems from a jointed contribution of all actors involved. Bearing in mind that seismic design is nothing else than proportioning properly seismic demand, in terms of acceleration and/or displacement, and the corresponding capacity, this paper gives a synthetic and informative overview on how to evaluate these two parameters. To shed some light on this, the concept of acceleration floor response spectrum (AFRS) is firstly brought in, along with basics of building structure-NSEs interaction, and is then deepened by means of calculation methods. Both the most rigorous method based on nonlinear dynamic simulations and the simplified analytical formulations provided by the NTC18 are briefly discussed and reviewed, trying to make them clearer even to readers with no structural/earthquake engineering background because, as a matter of fact, NSEs are often selected by architects and/or mechanical or electrical engineers. Lastly, a simple case study, representative of a European code-compliant five-storey masonry-infilled reinforced concrete frame building, is presented to examine differences between numerical and analytical AFRS and to quantify accuracy of different NTC18 procedures. |
Copyright: | © Beatrice Chichino et al. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
2.38 MB
- Über diese
Datenseite - Reference-ID
10638333 - Veröffentlicht am:
30.11.2021 - Geändert am:
17.02.2022