Testing and simulation of potential energy savings in renewing used split-type and window-type air-conditioners

Autor(en):

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Building Services Engineering Research and Technology, , n. 5, v. 41
Seite(n): 586-602
DOI: 10.1177/0143624419894438
Abstrakt:

In Saudi Arabia, air-conditioners ACs are responsible for 50% of electricity consumption due to hot weather conditions as well as the delay in implementing ACs standards. In this work, six used split-type and eight used window-type ACs that have ages from 3 to 32 years were tested according to American Society of Heating, Refrigerating and Air-Conditioning Engineers and Saudi Standard, Metrology and Quality Organization cooling test conditions and their performances were compared against new units that have 5.27 kW rated capacity. Test results show that coefficient of performance and cooling capacity of used split-type units compared to new one are 68% and 93%, respectively. For window-type, test results show that coefficient of performance and cooling capacity of used units compared to new one are 55% and 77%, respectively. The effect of replacing used compressor units with a new compressor was experimentally investigated. A model was developed using a commercially available software and was validated with experimental data. An economical map was developed to identify feasible ACs replacement regions.

Practical application: Using standard methods this study experimentally quantifies energy savings when used split- and window-type units are replaced with new units. This will help HVAC and energy professionals develop recommendations regarding replacing existing units for a given power tariffs. Additionally, tests were conducted with replacing compressors in used air-conditioners, rather than replacing the entire unit, so as to assist in answering how much energy savings, CO₂ and payback period can be achieved by simply replacing the compressors.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1177/0143624419894438.
  • Über diese
    Datenseite
  • Reference-ID
    10477106
  • Veröffentlicht am:
    18.11.2020
  • Geändert am:
    18.11.2020
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine