0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Stress Concentration Factors (SCFs) in Circular Hollow Section CHS-to-H-shaped Section Welded T-Joints under Axial Compression

Autor(en):
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Civil Engineering Journal, , n. 1, v. 5
Seite(n): 33
DOI: 10.28991/cej-2019-03091223
Abstrakt:

The aim of this paper is to investigate the effects of non-dimensional geometric parameters on stress concentration factors (SCFs) of circular hollow section CHS brace-to-H-shaped section T-connections under axial compression. This type of welded joints is used increasingly in steel construction. However, its fatigue design is not covered by codes, and its fatigue strength has not been given the deserved attention by researchers.  This research, however, bridges the gab on SCFs in this type of welded connections when being loaded in axial compression. here, parametric study based on the numerical analysis was performed to evaluate the effect of CHS brace diameter to H-shaped chord flange width ratio (β), H-shaped chord flange width to thickness ratio (2γ) and CHS brace thickness to H-shaped chord flange thickness ratio (τ) on SCFs in the brace and the chord of the connection. Based on practical considerations, the validity range of these parameters was 0.3 ≤ β ≤ 0.7, 16 ≤ 2γ ≤ 30 and 0.2 ≤ τ ≤ 0.1. Three-dimensional finite element (FE) study using commercial software ABAQUS was performed to study the hot spot stress distribution and hence SCFs in this type of welded joints. To begin with, the results of FEM were verified against available experimental data and good agreement was achieved. Afterwards, 48 joints were modeled in Abaqus to study the effect of geometrical parameter on SCFs in brace and chord. Based on the results of this extensive study, the effect of geometrical parameters was revealed. The paper, thus, shows that whilst β increases, SCFs in the brace and chord increases. Moreover, increasing the parameter 2γ results in an increase in SCFs in the two members. However, the change in τ has no significant effect on the SCFs in the brace or the chord. Values of SCFs are found to be between 2 and 7.

Copyright: © 2019 Abderlahman Ismaeel Hamdan,
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10340835
  • Veröffentlicht am:
    14.08.2019
  • Geändert am:
    02.06.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine