0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Stability of Air Content in Fresh Concretes with PCE-Based Superplasticizers

Autor(en): (D.Sc. (Tech.), Staff Scientist, Aalto University School of Engineering , Department of Civil Engineering , P.O.Box 12100, FIN-00076 , Espoo , Finland)
(M.Sc. Doctoral candidate, Aalto University School of Engineering , Department of Civil Engineering , P.O.Box 12100, FIN-00076 , Espoo , Finland)
(D.Sc. (Tech.), Professor of Practice, Concrete Technology, Aalto University School of Engineering , Department of Civil Engineering , P.O.Box 12100, FIN-00076 , Espoo , Finland)
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Nordic Concrete Research, , n. 1, v. 60
Seite(n): 145-158
DOI: 10.2478/ncr-2019-0093
Abstrakt:

Air contents of concrete are necessary for concrete durability in freeze-thaw exposure. According to the Finnish concrete code, the target value for air content varies between 4% and 5.5% for XF - exposure classes. Lately in Finland, some cases showed an elevation of air contents up to 15% in fresh air-entrained concrete at construction site and in drilled concrete samples.

The objectives of this study were to investigate the stability of air entrainment by measuring the air content elevation 30 minutes and 60 minutes after concrete mixing and investigating the concrete sensitivity to segregation. Composition of concretes used in this study include 7 different combination of PCE based superplasticizer and air-entraining agent admixtures, cement content of 425 kg/m³, two consistency classes S3 with water to cement ration of 0.33 and F5 with water to cement ration of 0.38. One cement type was used for all concrete mixes. The concretes were mixed for 2 minutes and 5 minutes mixing times.

The results show that the elevation of the air content of fresh concrete depends on the consistency of the concrete and on the used combination of superplasticizer and air-entraining agents. The higher consistency classes concretes have more risk of air elevation with some combinations of PCE-based superplasticizers and air-entraining agents. The results also indicate that short mixing time would not be enough to achieve total effectivity of some air-entraining agents, especially for higher consistency classes concrete.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.2478/ncr-2019-0093.
  • Über diese
    Datenseite
  • Reference-ID
    10705856
  • Veröffentlicht am:
    19.02.2023
  • Geändert am:
    19.02.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine