A series of specified domains in Nu-Muinteraction diagram are proposed to determine optimal reinforcement schemes for rectangular RC column sections subjected to uniaxial eccentric load. These domains divide the area covered by interaction diagram into four regions of safety zone, compression-controlled zone, balanced failure zone and tensioncontrolled zone, which can help engineer to understand all possibilities of section failure under varied reinforcement scheme when they carried out a section design for columns with numerical analysis. With the physical information included in the diagram, the domains help to establish logical judgment between practical reinforcement schemes specified by the Chinese code (GB50010-2010) and corresponding load combination (Nu, Mu) in interaction diagram, and also provide physical interpretation on any calculated result of steel consumption.

Copyright: © 2014 Yingjie Jia, Peng Chang, Jing Sun
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10384470
  • Veröffentlicht am:
    23.11.2019
  • Geändert am:
    02.06.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine