Shear Capacity of High-Strength Bolts in Long Connections
Autor(en): |
Raymond H. R. Tide
|
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Engineering Journal, März 2017, n. 1, v. 54 |
Seite(n): | 61-68 |
DOI: | 10.62913/engj.v54i1.1108 |
Abstrakt: |
Current design codes reduce the shear strength of individual bolts to account for potentially uneven distribution of force among the bolts including a 0.75/0.90 (83.3%) step function at 38 in. Available test data indicate there is no justification for a bolt shear strength reduction, especially the step function, due to the length of connection, provided that second-order effects are limited and gross and net section areas slightly exceed the AISC Specification limits (2010). A practical, empirical solution is proposed that maintains a reliability, ?, slightly greater than 4.0 for all connection lengths, using the current AISC resistance factor, ?, of 0.75. |