0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Seismic Response of GFRP-RC Interior Beam-to-Column Joints under Cyclic Static Loads

Autor(en): ORCID



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Buildings, , n. 11, v. 12
Seite(n): 1987
DOI: 10.3390/buildings12111987
Abstrakt:

A total of nine specimens were constructed and tested under cyclic loads to investigate the differences in seismic behavior between glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) joints and RC beam-to-column joints. The experimental parameters included stirrup ratios, axial pressure ratios and concrete strength of the beam-to-column joints. The cyclic loading test results showed that the GFRP-RC beam-to-column joints can withstand significantly high lateral deformations without exhibiting brittle failure. Moreover, the RC beam-to-column joint exhibited significantly higher energy dissipation and residual displacement than the GFRP-RC beam-to-column joint by 50% and 60%, respectively. Finally, a shear capacity calculation method for the core zone of this kind of joint was proposed, which agreed well with the experimental results.

Copyright: © 2022 by the authors; licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10699858
  • Veröffentlicht am:
    10.12.2022
  • Geändert am:
    10.05.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine