Seismic Response of GFRP-RC Interior Beam-to-Column Joints under Cyclic Static Loads
Autor(en): |
Rui Guo
Dan Yang Bin Jia Deyun Tang |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Buildings, 27 Oktober 2022, n. 11, v. 12 |
Seite(n): | 1987 |
DOI: | 10.3390/buildings12111987 |
Abstrakt: |
A total of nine specimens were constructed and tested under cyclic loads to investigate the differences in seismic behavior between glass fiber-reinforced polymer (GFRP)-reinforced concrete (RC) joints and RC beam-to-column joints. The experimental parameters included stirrup ratios, axial pressure ratios and concrete strength of the beam-to-column joints. The cyclic loading test results showed that the GFRP-RC beam-to-column joints can withstand significantly high lateral deformations without exhibiting brittle failure. Moreover, the RC beam-to-column joint exhibited significantly higher energy dissipation and residual displacement than the GFRP-RC beam-to-column joint by 50% and 60%, respectively. Finally, a shear capacity calculation method for the core zone of this kind of joint was proposed, which agreed well with the experimental results. |
Copyright: | © 2022 by the authors; licensee MDPI, Basel, Switzerland. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |