Seismic Performance of a Corroded Reinforce Concrete Frame Structure Using Pushover Method
Autor(en): |
Meng Zhang
Ran Liu Yaoliang Li Guifeng Zhao |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Advances in Civil Engineering, 2018, v. 2018 |
Seite(n): | 1-12 |
DOI: | 10.1155/2018/7208031 |
Abstrakt: |
SAP2000 software was used to build the finite element model of a six-storey-three-span reinforced concrete (RC) frame structure. The numerical simulation of the seismic performance of the RC frame structure incorporating different levels of rebar corrosion was conducted using pushover analysis method. The degradation characteristics of the seismic performance of the corroded structure under severe earthquake were also analyzed. The results show that the seismic performance of the RC frame decreased significantly due to corrosion of the longitudinal rebars. And the interstory drift ratios increase dramatically with the increasing of the corrosion rate. At the same time, the formation and development of plastic hinges (beam hinges or column hinges) will accelerate, which leads to a more aggravated deformation of the structure under rare earthquake action, resulting in a negative effect to the seismic bearing capacity of the structure. |
Copyright: | © 2018 Meng Zhang et al. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
1.57 MB
- Über diese
Datenseite - Reference-ID
10176668 - Veröffentlicht am:
30.11.2018 - Geändert am:
02.06.2021