Seismic Analysis of the Bell Tower of the Church of St. Francis of Assisi on Kaptol in Zagreb by Combined Finite-Discrete Element Method
Autor(en): |
Ivan Balić
Hrvoje Smoljanović Boris Trogrlic Ante Munjiza |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Buildings, 27 Juli 2021, n. 8, v. 11 |
Seite(n): | 373 |
DOI: | 10.3390/buildings11080373 |
Abstrakt: |
The paper presents a failure analysis of the bell tower of the church of St. Francis of Assisi on Kaptol in Zagreb subjected to seismic activity using the finite-discrete element method—FDEM. The bell tower is a masonry building, and throughout history it has undergone multiple damages and reconstructions. It was significantly damaged during the earthquake in Zagreb which occurred on 22 March 2020 with a magnitude of 5.5. The analysis was performed on a simplified FDEM 2D numerical model which corresponds to the structure in its current pre-disaster state and the structure after the proposed post-disaster reconstruction. The obtained results showed a good agreement of the crack pattern in the numerical model and the cracks that occurred due to these earthquakes. In addition, the conclusions based on the conducted analysis can provide a better insight into the behaviour and serve as guidelines to engineers for the design of such and similar structures. |
Copyright: | © 2021 by the authors; licensee MDPI, Basel, Switzerland. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
3.63 MB
- Über diese
Datenseite - Reference-ID
10625815 - Veröffentlicht am:
26.08.2021 - Geändert am:
14.09.2021