0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Research on Optimization of Climate Responsive Indoor Space Design in Residential Buildings

Autor(en): ORCID



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Buildings, , n. 1, v. 12
Seite(n): 59
DOI: 10.3390/buildings12010059
Abstrakt:

This paper first analyzes the climate characteristics of five typical cities in China, including Harbin, Beijing, Shanghai, Shenzhen and Kunming. Then, based on Grasshopper, Ladybug and Honeybee analysis software, according to the indoor layout of typical residential buildings, this research extracts design parameters such as the depth and width of different rooms and their window-to-wall ratios etc., to establish a climate responsive optimization design process with indoor lighting environment comfort, with heating and cooling demand as the objective functions. Meanwhile, based on Monte Carlo simulation data, ANN (Artificial Neural Network) is used to establish a prediction model to analyze the sensitivity of interior design parameters under different typical cities’ climatic conditions. The study results show that the recommended values for the total width and total depth of indoor units under the climatic conditions of each city are both approximately 14.97 m and 7.88 m. Among them, under the climatic conditions of Harbin and Shenzhen, the design parameters of residential interiors can take the recommended value of UDI optimal or nZEB optimal. While the recommended values of window-to-wall ratios for the north bedroom, master bedroom and living room in Shanghai residential interiors are 0.26, 0.32 and 0.33, respectively. The recommended value of the window-to-wall ratio of the master bedroom in Kunming residences is 0.36, and that of the remaining rooms is between 0.15 and 0.18. The recommended values of window-to-wall ratios for the master bedroom and living room in Beijing residences are 0.41 and 0.59, respectively, and that for the remaining rooms are 0.15. The multi-objective optimization process based on parametric performance simulation used in the study can effectively assist architects in making energy-saving design decisions in the preliminary stage, allowing architects to have a case to follow in the actual design operation process.

Copyright: © 2021 by the authors; licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10657670
  • Veröffentlicht am:
    17.02.2022
  • Geändert am:
    01.06.2022
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine