0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Real-time Hybrid Test on a Semi-actively Controlled Building Structure Equipped with Full-scale MR Dampers

Autor(en):






Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Journal of Intelligent Material Systems and Structures, , n. 18, v. 21
Seite(n): 1831-1850
DOI: 10.1177/1045389x10390253
Abstrakt:

The real-time hybrid testing method (RT-HYTEM) is a structural testing technique in which the numerical integration of the equation of motion for a numerical substructure and the physical testing for an experimental substructure are performed simultaneously in real-time. This article presents the quantitative evaluation of the seismic performance of a building structure installed with a magnetorheological (MR) damper using RT-HYTEM. A building model is identified from the force-vibration testing results of a full-scale five-story building and is used as the numerical substructure, and an MR damper corresponding to an experimental substructure is physically tested using a universal testing machine (UTM). First, the force required to drive the displacement of the story, at which the MR damper is located, is measured from the load cell attached to the UTM. The measured force is then returned to a control computer to calculate the response of the numerical substructure. Finally, the experimental substructure is excited by the UTM with the calculated response of the numerical substructure. The RT-HYTEM implemented in this study is validated because the real-time hybrid testing results obtained by application of sinusoidal and earthquake excitations and the corresponding analytical results obtained using the Bouc-Wen model as the control force of the MR damper with respect to input currents are in good agreement. Also, the results from RT-HYTEM for the passive -on and -off control show that the structural responses did not decrease further by the excessive control force, but decreased due to the increase of the current applied to the MR damper. Also, two semi-active control algorithms (modulated homogeneous friction and the clipped-optimal control algorithms) are applied to the MR damper in order to optimally control the structural responses. To compare the RT-HYTEM and numerical results, Bouc-Wen model parameters are identified for each input current. The results of the comparison of experimental and numerical responses show that it is more practical to use RT-HYTEM in semi-active devices such as MR dampers. The test results show that a control algorithm can be experimentally applied to the MR damper using RT-HYTEM. This article provides a discussion on each algorithm with respect to the seismic performances.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1177/1045389x10390253.
  • Über diese
    Datenseite
  • Reference-ID
    10673377
  • Veröffentlicht am:
    02.06.2022
  • Geändert am:
    02.06.2022
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine