0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

The performance of pressure cells for sprayed concrete tunnel linings

Autor(en):




Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Géotechnique, , n. 2, v. 52
Seite(n): 107-115
DOI: 10.1680/geot.2002.52.2.107
Abstrakt:

The paper examines the factors that affect the performance of tangential cells embedded in shotcrete tunnel linings. New data, derived from field monitoring, numerical modelling, and calibration tests carried out to simulate the embedment and crimping processes, are presented. These suggest that although well-designed embedded total pressure cells will have cell action factors close to unity, they cannot be assumed to provide reasonable estimates of the stresses within sprayed concrete linings, unless the influences of installation effects, temperature changes, shrinkage and subsequent crimping can be taken into account.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1680/geot.2002.52.2.107.
  • Über diese
    Datenseite
  • Reference-ID
    10674113
  • Veröffentlicht am:
    29.05.2022
  • Geändert am:
    29.05.2022
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine