Performance Flexural of RC Beams Without Concrete at Tension Cross-section

Autor(en): ORCID



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Civil Engineering Journal, , n. 11, v. 8
Seite(n): 2560-2572
DOI: 10.28991/cej-2022-08-11-014
Abstrakt:

This study aims to analyze the flexural capacity of RC without concrete in a tension cross-section using an experimental method. The number of specimens is three pieces, namely a spiral reinforced concrete beam (SBC) and a vertical reinforced concrete beam (CBN); both of these blocks are without concrete in the cross-section of the reinforcement and 60D tensile steel reinforcement in the support area, where D is the primary diameter, and a conventional concrete beam as the control beam (CB). The beam size is 3100×150×200 mm. The beams are supported by simple supports with a span of 3000 mm. The concrete in the structural beam elements, which work optimally to withstand the load, is the outermost fibre part of the side, while the concrete on the tension side does not have a direct role in determining the magnitude of the resisting moment. Therefore, the quality of the concrete in the concrete beam section must be optimized, while the concrete in the tension section must be minimized. Eliminating concrete in tension areas reduces the construction's self-weight and use of concrete-making materials. The main variables in this research are bending behaviour and crack pattern. The beam specimens were tested with two-point loading monotonically. By observing the crack pattern and failure mode, the results showed an increase in the capacity load of SBC by 21.58% CBN but a decrease of 27.57% compared to the CB control beam. Flexural cracks and beam failures resembled under-reinforcing. The flexural capacity was analyzed based on static analysis and then validated by calculating the ratio between the theoretical nominal moment and the experimental moment. This finding shows that changing the conventional shear reinforcement model to spiral can increase the flexural of the beam without concrete in the tension cross-section. 

Copyright: © 2022 Astiah Amir, Aulia Rahman, Lissa Opirina, Fadli Idris
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10702834
  • Veröffentlicht am:
    10.12.2022
  • Geändert am:
    15.02.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine