0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

P-V-M Interaction Curves for Seismic Design of Steel Column Base Connections

Autor(en):

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Engineering Journal, , n. 3, v. 39
Seite(n): 154-165
DOI: 10.62913/engj.v39i3.779
Abstrakt:

Recent studies on connections have shown that the beam bending theory cannot predict the flow of forces near the connection regions. In this paper, a new truss analogy model has been proposed to better represent the flow of forces near the column base connections. Also, shear moment strength envelopes, generated for different levels of axial load using the hysteretic stress-strain curves for steel, are presented. The moment and shear demand for the design of column base connection elements are calculated using the normalized P-V-M interaction curves. Appropriate strength factors applied to the moment capacity of the column section to account for the uncertainty in the estimation of yield stress, strain hardening, compactness of the section, and slenderness of the member are discussed. Finally, a generalized procedure for the capacity design of column base connections is proposed.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.62913/engj.v39i3.779.
  • Über diese
    Datenseite
  • Reference-ID
    10782725
  • Veröffentlicht am:
    17.05.2024
  • Geändert am:
    17.05.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine