The experimental setup implements a simplified PASSYS test cell construction, which is combined with a detailed simulation to reduce measurement effort. To analyze the cell’s dynamic behavior, the test cell was closely monitored with thermal sensors, and different static and dynamic heating modes were applied during a three-week calibration period. Co-heating tests were performed for steady-state measurements and cyclic heating periods account for the transient behavior of the test cell. The cells response was compared to the results of transient simulations with the software packet Modelica. The equation based Modelica framework allowed a detailed transient thermal simulation of the test cell’s dynamic to be set up that shows close agreement with the measurements. In addition, the flexibility of Modelica allowed unforeseen events affecting the experimental setup to be replicated, thereby ensuring an uninterrupted heat flow history of all surfaces. More than 96% of the predicted air temperatures (1 min resolution) match the experimental values within an error band of ±1.5 K, and 90% of all predictions are within ±1.0 K. |
Copyright: | © 2019 by the authors; licensee MDPI, Basel, Switzerland. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
4.09 MB
- Über diese
Datenseite - Reference-ID
10375979 - Veröffentlicht am:
02.10.2019 - Geändert am:
02.06.2021