Abstrakt: |
In recent years, steel-concrete composite shear walls have been widely used in enormous high-rise buildings. Due to their high strength and ductility, enhanced stiffness, stable cycle characteristics and large energy absorption, such walls can be adopted in auxiliary buildings, surrounding the reactor containment structure of nuclear power plants to resist lateral forces induced by heavy winds and severe earthquakes. The current study aims to investigate the seismic behaviour of composite shear walls and evaluate their performance in comparison with traditional reinforced concrete (RC) walls when subjected to cyclic loading. A three-dimensional finite element model is developed using ANSYS by emphasising constitutive material modelling and element type to represent the real physical behaviour of complex shear wall structures. The analysis escalates with parametric variation in reinforcement ratio, compressive strength of the concrete wall, layout of shear stud and yield stress of infill steel plate. The modelling details of structural components, contact conditions between steel and concrete, associated boundary conditions and constitutive relationships for the cyclic loading are explained. The findings of this study showed that an up to 3.5% increase in the reinforcement ratio enhanced the ductility and energy absorption with a ratio of 37% and 38%, respectively. Moreover, increasing the concrete strength up to 55 MPa enhanced the ductility and energy absorption with ratios of 51% and 38%, respectively. Thus, this improves the contribution of concrete strength, while increasing the yield stress of steel plate (to 380 MPa) enhanced the ductility (by a ratio of 66%) compared with the reference model. The present numerical research shows that the compressive strength of the concrete wall, reinforcement ratio, layout of shear stud and yield stress of infill steel plate significantly affect ductility and energy absorption. Moreover, this offers a possibility for improving the shear wall’s capacity, which is more important. |
Copyright: | © 2022 by the authors; licensee MDPI, Basel, Switzerland. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
13.58 MB
- Über diese
Datenseite - Reference-ID
10688587 - Veröffentlicht am:
13.08.2022 - Geändert am:
10.11.2022