A Method for Extracting Contours of Building Facade Hollowing Defects Using Polarization Thermal Images Based on Improved Canny Algorithm

Autor(en):






Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Buildings, , n. 10, v. 13
Seite(n): 2563
DOI: 10.3390/buildings13102563
Abstrakt:

During the service process of high-rise buildings, hollowing defects may be produced in the decorative layer, which not only affect the appearance, but also create a safety hazard of wall covering and shattered plaster peeling. Numerous studies have shown that hollowing can be detected using infrared thermal imagery under normal conditions. However, it is difficult to detect the edge and calculate the area of the hollowing on an exterior facade accurately because of the low contrast and fuzzy boundaries of the obtained infrared thermal images. To address these problems, a method for extracting the contours of building facade hollowing defects using polarization thermal images based on an improved Canny algorithm has been proposed in this paper. Firstly, the principle of thermal polarization imaging was introduced for hollowing detection. Secondly, considering the shortcomings of the Canny edge detection algorithm and the features of polarization thermal images, an improved Canny edge detection algorithm is proposed, including adaptive bilateral filtering to improve noise reduction ability while ensuring defect edges are not virtualized, Laplacian sharpening and histogram equalization to achieve contour sharpening and contrast enhancement, and eight-direction gradient templates for calculating image gradients, which make interpolation with non-maximum suppression more accurate, and the Tsallis entropy threshold segmentation algorithm based on the OTSU algorithm verification makes the image contour information more complete and accurate. Finally, a long-wave infrared polarization thermal imaging experimental platform was established and validation experiments were conducted. The experimental results demonstrate that the distinct, smooth, and precise location edges of the hollowing polarization infrared thermal images can be obtained, and the average error of the detected hollowing area is about 10% using the algorithm proposed in this paper.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10744299
  • Veröffentlicht am:
    28.10.2023
  • Geändert am:
    07.02.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine