0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Mechanical Properties of Pervious Recycled Aggregate Concrete Reinforced with Sackcloth Fibers (SF)

Autor(en): (Department of Environmental Science, Faculty of Environment, Kasetsart University, Bangkok 10900, Thailand)
ORCID (Department of Environmental Science, Faculty of Environment, Kasetsart University, Bangkok 10900, Thailand)
(Department of Environmental Science, Faculty of Environment, Kasetsart University, Bangkok 10900, Thailand)
(Department of Environmental Science, Faculty of Environment, Kasetsart University, Bangkok 10900, Thailand)
ORCID (Research and Innovation Development Unit for Infrastructure and Rail Transportation Structural System (RIDIR), Faculty of Engineering, Srinakharinwirot University, Nakhonnayok 26120, Thailand)
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Infrastructures, , n. 2, v. 8
Seite(n): 38
DOI: 10.3390/infrastructures8020038
Abstrakt:

The excessive production of construction waste is a significant concern as it requires proper disposal and may become economically unfeasible. Reusing construction waste in producing new concrete can substantially reduce the disposal requirements of construction waste. In addition, this results in a sustainable solution for the rapidly depleting natural resources of concrete. Pervious concrete may contain up to 80% coarse aggregates and could be an exceptional host for reusing construction waste. This study aimed to investigate the mechanical properties of pervious concrete constructed with natural and recycled aggregates. The substandard properties of recycled aggregates were improved by adding natural fibers from sackcloth. This study presents an experimental program on 45 samples of pervious concrete with air void ratios and the size of coarse aggregates as the parameters of interest. The compressive strength of the pervious concrete decreased by increasing the air void ratio regardless of the size of the aggregates. The type of aggregates did not influence the permeability of pervious concrete, and the maximum temperature in pervious concrete increased as the quantity of air void ratios increased. The decrease in compressive strength was 40–60% as the void ratio was increased from 10–30% for all types of concrete mixes, such as natural and recycled aggregates. The permeability of small-size aggregates with 10% designed air void ratios for natural and recycled aggregates with sackcloth was 0.705 cm/s.

Copyright: © 2023 the Authors. Licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10722733
  • Veröffentlicht am:
    22.04.2023
  • Geändert am:
    10.05.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine