Lublin University of Technology, Faculty of Civil Engineering and Architecture, Department of Construction Management
Autor(en): |
Tadeusz Ciężak
|
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Budownictwo i Architektura, Dezember 2013, n. 4, v. 12 |
Seite(n): | 219-224 |
DOI: | 10.35784/bud-arch.1976 |
Abstrakt: |
This paper presents a methodology of dimensioning of double reinforced concrete beams which are reinforced in the light of the requirements of the EC2 [1] in two variants. In the first variant, the limiting value of the compression zone was determined on the basis of limiting strains of concrete and steel. The maximum degree of concrete reinforcement of bending elements are assumed in the second case. The considered problem is illustrated by computational examples in relation to the concrete classes C30/37 and C70/85. Results of the calculations cannot be the basis for generalizations, however, differences in the section of the reinforcement determined in both cases are small and do not exceed 6%. |
- Über diese
Datenseite - Reference-ID
10476035 - Veröffentlicht am:
25.11.2020 - Geändert am:
25.11.2020