Low-coherent fiber-optic interferometry for in situ monitoring the corrosion-induced expansion of pre-stressed concrete cylinder pipes
Autor(en): |
Heming Wei
Kaixing Liao Xuefeng Zhao Xianglong Kong Pinglei Zhang Changsen Sun |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Structural Health Monitoring, September 2018, n. 5-6, v. 18 |
Seite(n): | 1862-1873 |
DOI: | 10.1177/1475921719826360 |
Abstrakt: |
The corrosion-induced expansion of pre-stressed concrete cylinder pipes shapes a major determining factor in the durability of most pipeline systems. However, a structure extended in a very large span and accompanied by a slow corrosion-induced structural damage is still a challenge in practice. Here, a low-coherent fiber-optic interferometry is proposed for in situ measuring the corrosion-induced expansion by directly circling the sensing optical fiber on the outer surface of the pipe. Since the accuracy of the absolute deformation measurement by the low-coherent fiber-optic interferometry can reach 3–5 μm, we are able to improve the sensitivity by choosing the length of the sensing fiber. In the experiment, we employ 50-m sensing fiber; therefore, a resolution of about 0.1 microstrains had been approached. We chose 12 places along the pipeline as the corrosion-induced expansion monitoring points. On monitoring for about half a year, a non-uniform interface in structure, such as the repaired places, was found as a key factor of the corrosion-induced expansion development, which could be a reference for the further health care of the pipeline structures. |
- Über diese
Datenseite - Reference-ID
10562260 - Veröffentlicht am:
11.02.2021 - Geändert am: