Load-Carrying Capacity of Compressed Wall-Like RC Columns Strengthened with FRP
Autor(en): |
Alberto Maria Avossa
Vincenzo Picozzi Francesco Ricciardelli |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Buildings, 30 Juni 2021, n. 7, v. 11 |
Seite(n): | 285 |
DOI: | 10.3390/buildings11070285 |
Abstrakt: |
The analytical prediction of the effectiveness of fiber-reinforced polymer (FRP) in the confinement of a rectangular reinforced concrete (RC) column with a high aspect ratio (wall-like) still has an uncertain solution. In this paper, a numerical investigation of the axial response of RC wall-like columns strengthened with FRP systems was developed. Analytical solutions proposed in the literature for the assessment of the axial load capacity were presented and compared with each other and with the available experimental results. Moreover, non-linear finite element analysis was carried out, and the results were discussed, providing a simple model for the assessment of the axial compressive strength of wall-like RC columns strengthened with FRP. |
Copyright: | © 2021 by the authors; licensee MDPI, Basel, Switzerland. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |