IWSHM 2017: Application of guided wave methods to quantitatively assess healing in osseointegrated prostheses

Autor(en):

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Structural Health Monitoring, , n. 6, v. 17
Seite(n): 1377-1392
DOI: 10.1177/1475921718782399
Abstrakt:

Osseointegrated prosthesis is essentially a prosthetic fixture surgically implanted into the bone that extends out of the limb so that an artificial limb can be attached. While osseointegrated prostheses can dramatically improve the quality of life of amputees, there remains a lack of quantitative evidence of the osseointegration process that occurs at the bone–prosthesis surface after surgery. This study advances a sensing strategy that employs piezoelectric elements mounted to the percutaneous end of the prosthesis to generate guided waves that propagate along the length of the prosthesis fixture. The properties of the guided waves exhibit sensitivity to both the degree of bone healing that occurs at the prosthesis surface and the movement of the prosthesis due to loss of osseointegration. Use of the prosthesis as a wave guide offers care providers a quantitative approach to determining when an osseointegrated prosthesis can be loaded and tracks the integrity of osseointegration over the lifespan of the amputee. The study validates the proposed guided wave strategy using a prosthesis model consisting of a solid titanium rod implanted in an adult femoral bone. First, a high-fidelity finite element model is created to study changes in guided waves as a result of bone healing. A laboratory model is also adopted using a synthetic femoral bone identical to that modeled in the finite element model. The energy of the first longitudinal wave mode introduced at the percutaneous end of the prosthesis provides a repeatable metric for accurate assessment of both osseointegration and prosthesis pullout from the bone. The results of this study reveal that the energy of the longitudinal wave mode decreases by nearly half during the osseointegration healing process. In addition, the wave energy is also found to increase as the osseointegrated fixture loosens and is withdrawn from the bone.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1177/1475921718782399.
  • Über diese
    Datenseite
  • Reference-ID
    10562178
  • Veröffentlicht am:
    11.02.2021
  • Geändert am:
    19.02.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine