0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

In Search for Untapped Energy-Saving Potential in Green and Smart Higher Educational Buildings—An Empirical Case Study Involving the Building Occupants

Autor(en): ORCID


Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Buildings, , n. 12, v. 13
Seite(n): 3103
DOI: 10.3390/buildings13123103
Abstrakt:

Energy-intense activities and the unpredictable and complex behavior of building occupants lead to an increase in building energy demand. It is, therefore, crucial to study underlying factors for building energy demand related to the users. Higher educational buildings are relevant to study for several reasons: they host the future workforce and citizens, they are predicted to increase in numbers, and they represent a building type less studied. Furthermore, green-rated buildings equipped with smart building systems also represent a research gap that is relevant to address since such a building design involves IoT-functionalities and digital features for the building occupants to interact with. There is also a conceivable risk that if the users know that the building is green-rated and technologically advanced, this may alter their perception of the building operation and thus their behavior. To study the relationship between building occupants and such green and smart educational structure, a survey was conducted in a Swedish higher educational building; as a result, 300 responses were collected and analyzed. The responses revealed that the building occupants act with energy awareness, and they are conscious about energy-saving behaviors. One building feature in particular was studied: the Digital Room Panels (DRPs). The DRP allows the building occupants to modify the indoor temperature and is, therefore, essential for thermal comfort. One key finding from the survey revealed that 70% of the building occupants did not know how the DRPs operate. This study argues that this result can be explained with a lack of communication and user friendliness. Inadequate interactions with building systems could also result in opportunities for energy saving might not be realized. The findings of this case study led to valuable recommendations and suggestions for future research endeavors.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10754194
  • Veröffentlicht am:
    14.01.2024
  • Geändert am:
    07.02.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine