0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

In-plane Shear Strengthening of Unreinforced Masonry Walls Using GFRP Jacketing

Autor(en):

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Periodica Polytechnica Civil Engineering
DOI: 10.3311/ppci.11311
Abstrakt:

In this paper, it is presented the experimental results of a campaign on diagonal compression tests, as of ASTM E519-02, to assess and compare the in-plane behavior of standard size of 1200 × 1200 × 250 mm, for three unreinforced and three reinforced wall panels by glass fiber reinforced polymer (GFRP) embedded in an inorganic matrix.From the diagonal compression test results, were determined some of the main mechanical parameters such as: shear strength, modulus of rigidity and ductility, before and after application of the reinforcement.The experimental results showed that the GFRP reinforced panels exhibited a significant increase of 127% in shear resistance, 1100% in ductility and 650% in modulus of rigidity when compared to unreinforced panels.It was concluded that this technique provided satisfactory results and can be considered a suitable method for repair of masonry structures.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.3311/ppci.11311.
  • Über diese
    Datenseite
  • Reference-ID
    10536612
  • Veröffentlicht am:
    01.01.2021
  • Geändert am:
    19.02.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine