0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Imaging of local porosity/voids using a fully non-contact air-coupled transducer and laser Doppler vibrometer system

Autor(en):



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Structural Health Monitoring, , n. 2, v. 16
Seite(n): 164-173
DOI: 10.1177/1475921716668843
Abstrakt:

This study exploits the feasibility of imaging zones of local porosity/voids simulated by introducing microspheres during layup of a unidirectional carbon fiber–reinforced polymer composite panel. A fully non-contact hybrid system primarily composed of an air-coupled transducer and a laser Doppler vibrometer was used for imaging the local porosity/void zones from the guided wave response. To improve image resolution, several preprocessing techniques are performed. The wavefield reconstructed from the laser Doppler vibrometer measurements was first “denoised” using a one-dimensional wavelet transform in the time domain followed by a two-dimensional wavelet transform in the spatial domain. From the total wavefield, the much weaker backscattered waves were separated from the stronger incident wave by frequency–wavenumber domain filtering. In order to further enhance the signal-to-noise ratio and sharpen the image, the attenuation of incident wave propagation to the damage site was compensated through two proposed weight functions. Finally, a zero-lag cross-correlation was performed for imaging the zone where the compensated incident and backscattered waves were in phase. This improved imaging condition, the “denoised” weighted zero-lag cross-correlation, was proposed and tested for defect imaging in the composite panel with eight intentionally introduced zones of high porosity/voids of varying diameters (1.59–6.35 mm) and depths (0.36–1.08 mm). As expected, the sensitivity of the non-contact air-coupled transducer/laser Doppler vibrometer hybrid system was limited by the wavelength of the excitation signal. The system incorporated with the denoised weighted zero-lag cross-correlation imaging condition for guided wave interrogation gave similar image quality in comparison with that by the immersion C-scan.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1177/1475921716668843.
  • Über diese
    Datenseite
  • Reference-ID
    10561996
  • Veröffentlicht am:
    11.02.2021
  • Geändert am:
    19.02.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine