Hygrothermal performance of cold ventilated attics above different horizontal ceiling constructions: Full-scale test building

Autor(en):


Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Journal of Building Physics, , n. 1, v. 44
Seite(n): 67-91
DOI: 10.1177/1744259119894028
Abstrakt:

It is often assumed that reduced heat flux to a ventilated attic reduces the temperature and thereby increases the relative humidity. Consequently, the importance of having a tight air and vapour barrier in the ceiling becomes more important with increased insulation. Therefore, in Denmark, the recommendation is to have a tight vapour barrier when re-insulating ceilings against cold ventilated attics to a total of 150-mm insulation material. The recommendation is independent of the insulation material’s hygroscopic properties or the indoor moisture level. The aim of this project was to test the relevance of the recommendation through testing in a full-scale test building (7 × 22 m) with a series of six different ceilings with or without a vapour barrier and variation in the insulation material comprising insulation thickness and its hygroscopic properties. The examination was performed with a controlled indoor climate after an European humidity classes 1–3 and a natural outdoor climate. The study showed very little differences in temperature and relative humidity in the cold ventilated attics, while the humidity class of the indoor climate significantly affects the absolute moisture content in the attic. However, the climate in the attic did not cause mould growth in the test sections, even for humidity class 3. Consequently, in the test building the thickness or hygroscopic properties of the insulation material did not have a significant effect on the moisture level in attics and did not determine whether a vapour barrier should be installed. In this study with the given climate, a vapour barrier is unnecessary in well-ventilated attics if the ceiling is airtight.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1177/1744259119894028.
  • Über diese
    Datenseite
  • Reference-ID
    10519590
  • Veröffentlicht am:
    10.12.2020
  • Geändert am:
    19.02.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine