0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Fire resistance of slender section beams - Subjected to lateral torsional buckling

Autor(en):



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Steel Construction, , n. 3, v. 7
Seite(n): 188-192
DOI: 10.1002/stco.201410031
Abstrakt:

The paper shows experimental and numerical research into slender cross-section beams in case of fire. The topic is very important because little investigation has been made and little experimental data has been collected so far. In the framework of the RFCS project FIDESC4 - Fire Design of Steel Members with Welded or Hot-rolled Class 4 Cross-sections, several simple supported beams were tested at elevated temperature at the Czech Technical University in Prague.
Currently, Eurocode 3 contains a number of simple rules for design of slender Class 4 cross-sections which, based on recent numerical simulations, proved themselves to be over-conservative. Through refining these rules, material savings could be achieved, which would lead to greater competitiveness of the steel structures. This is being covered in existing research, but is not published in this paper, which is limited to lateral torsional buckling behaviour only.
Determination of the bending resistance for members subjected to lateral torsional buckling of Class 1-3 cross-sections at elevated temperature is based on the same principles as the design at room temperature, according to EC 3 part 1-1 [1]. However, it differs in using only one imperfection factor for all types of cross-sections. The informative Annex E of the standard (EC 3 part 1-2 [2]) recommends using the design formulas for slender (Class 4) sections as well. But there is a restriction of the critical temperature value and a different reduction of yield strength is used (0.2 % proof strength for Class 4 instead of 2.0 % proof strength for stockier Class 1-3 sections). For the non-uniform members (variable section height), a limited design procedure is given in EC 3 part 1-1 [1]. This is applicable for room temperature only. The possibility of using these rules for fire design is not yet confirmed.

Stichwörter:
3D-Biegedrillknicken Feuerwiderstand numerische Modellierung
Verfügbar bei: Siehe Verlag
Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1002/stco.201410031.
  • Über diese
    Datenseite
  • Reference-ID
    10070747
  • Veröffentlicht am:
    02.12.2014
  • Geändert am:
    04.02.2015
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine