Experimental Study on New-typed Prefabricated Shear Walls with Vertical Joint Under Different Shear Span Ratio

Autor(en):




Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: The Open Civil Engineering Journal, , n. 1, v. 11
Seite(n): 965-971
DOI: 10.2174/1874149501711010965
Abstrakt:

Objective:

To study the connection behavior of the vertical joint and the effect of shear span ratio on the mechanical behavior of the new-typed prefabricated shear walls with the vertical joint, quasi-static tests for three walls have been carried out.

Results and Conclusion:

The results show that the shear span ratio has significant effect on the mechanical behavior of the new-typed prefabricated shear walls, and the new-typed prefabricated shear walls have good ductility, all the ductility factors are greater than 4.0. The study also proves that the construction of the vertical joint is reasonable and its connection property is reliable. The vertical joint which can ensure the effective connection between different assembly units on horizontal direction can be used to guide the practical engineering.

Copyright: © 2017 Gang Wang et al.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10175201
  • Veröffentlicht am:
    02.08.2019
  • Geändert am:
    02.06.2021
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine