Experimental Behaviour of Steel Tubular Columns for Varying in Filled Concrete
Autor(en): |
P. Sangeetha
R. Senthil |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Archives of Civil Engineering, Dezember 2017, n. 4, v. 63 |
Seite(n): | 149-160 |
DOI: | 10.1515/ace-2017-0046 |
Abstrakt: |
This paper investigates the behaviour of axially-loaded tubular columns filled with M20 grade concrete and partially replaced concrete. The parameters varying in the study are slenderness ratio (13.27, 16.58 & 19.9), and normal M20 grade concrete, partially replaced quarry dust and concrete debris. The effects of the various concrete mixes and composite action between the steel tube and the concrete core are studied and a graph visualizing the differences between the load carrying capacity and the axial deflection is plotted. Some of the performance indices like the Ductility Index (DI), Concrete Contribution Ratio (CCR), Confinement Index (θ) and Strength Index (SI) are also evaluated and compared amongst the CFST columns. From the results it has been noted that an increase in the L/D ratio decrease the behaviour of the composite columns irrespective of the in filled materials. The composite action was achieved in the CFST columns filled with partially replaced quarry dust and concrete debris when compared with hollow steel columns. The load carrying capacity of the CFST column increases by 32 % compared with the hollow tubular columns. |
- Über diese
Datenseite - Reference-ID
10476767 - Veröffentlicht am:
25.11.2020 - Geändert am:
25.11.2020