Experiment Study on Dynamic Effects of Tower-Line Systems Induced by Ice Shedding
Autor(en): |
Xianzhong Xie
Yuanjie Wu Kaiyuan Liang Sai Liu Jian Peng |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Advances in Civil Engineering, Januar 2020, v. 2020 |
Seite(n): | 1-9 |
DOI: | 10.1155/2020/6241789 |
Abstrakt: |
Taking the 220 kV transmission line as the prototype, a test model of the double-span tower-line system with a scale ratio of 1 : 20 was proposed on the basis of dynamic similarity theory. 14 different working conditions including zippered, simultaneous, entire, and local ice-shedding were controlled and realized by use of the program-controlled mode. The displacement transient responses of transmission line under these ice-shedding conditions were analyzed in detail. The results show that the variation laws of the ice-shedding dynamic-load coefficient and the jump height with the velocity, quantity, and position of the ice-shedding are obtained, which can provide references for the design of the transmission tower-line system. |
Copyright: | © Xianzhong Xie et al. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
1.56 MB
- Über diese
Datenseite - Reference-ID
10414954 - Veröffentlicht am:
02.03.2020 - Geändert am:
02.06.2021