Equivalent Modal Damping Ratios of a Composite Tube-Type Tall Building to Dynamic Wind Loading
Autor(en): |
B. C. Huang
K. M. Lam A. Y. T. Leung Y. K. Cheung |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Shock and Vibration, 1996, n. 2, v. 3 |
Seite(n): | 99-105 |
DOI: | 10.1155/1996/608684 |
Abstrakt: |
This article discusses computing methods of the equivalent modal damping ratio for a composite tube-type tall building. The equivalent damping ratio of a composite structure under wind-induced vibrations encompasses the combined effects from the different values of damping, mass, and stiffness of the external and internal tubes. A detailed method incorporating Rayleigh damping and the transfer matrix method is proposed for the determination of the equivalent modal damping ratio. A simplified method for engineering applications is also proposed. Results for a 40-story building are presented exemplifying the computation and relationships between the properties of the external and internal tubes. |
Copyright: | © 1996 B.C. Huang, K.M. Lam, A.Y.T. Leung, Y.K. Cheung |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 3.0 (CC-BY 3.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
1.98 MB
- Über diese
Datenseite - Reference-ID
10676383 - Veröffentlicht am:
28.05.2022 - Geändert am:
01.06.2022