Abstrakt: |
In the paper, fire resistance of linear joints seal made of elastomer spacers under standard fire conditions, and thermal degradation range of EPDM elastomeric spacers are investigated. The geometry of elastomer spacer joints is important not only for their load capacity under normal conditions - thickness, width, and cavity depth can also influence fire resistance performance. Linear joints of different thicknesses and widths have been tested. The fire insulation and fire integrity were verified for various arrangements. Relatively low thermal degradation rates have been measured, given that EPDM is a combustible material. |