0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Design of I-Beam to Box-Column Connections Stiffened Externally

Autor(en):


Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Engineering Journal, , n. 4, v. 30
Seite(n): 141-149
DOI: 10.62913/engj.v30i4.1279
Abstrakt:

This paper is concerned with I-beam to box-column connections stiffened externally. A design method to determine the dimensions of T-stiffeners is proposed. Connections of I-beams and box columns for a wide range of dimensions were studied by the finite-element method and found to satisfy the basic design criteria for a moment connection. The Ramberg-Osgood function was used to curve-fit the moment-rotation curves based on the geometric parameters of the connections and the results are found to agree well with those from the finite-element analyses. Finally, the design procedure and the curve-fitting parameters were compared with the experimental results of a four-way connection tested to failure.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.62913/engj.v30i4.1279.