0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Autor(en):



Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Engineering Journal, , n. 1, v. 23
Seite(n): 9-23
DOI: 10.62913/engj.v23i1.457
Abstrakt:

A series of experiments were conducted to verify the design criteria for beam-column joints under extreme seismic conditions for a 47-story building in San Francisco. The halfscale cruciform specimens were exceptionally large, requiring 18 in. deep sections. The overall size of the specimens was the largest ever tested in the U.S. for this kind of application. The data on the behavior of such large moment-resisting joints under severe cyclic loading are very limited. The experimental evidence clearly supports the use of stiffeners and doubler plates at the joints for the cross-sectional geometries tested. The results are of direct relevance to seismic design of many steel buildings.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.62913/engj.v23i1.457.
  • Über diese
    Datenseite
  • Reference-ID
    10783079
  • Veröffentlicht am:
    17.05.2024
  • Geändert am:
    17.05.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine