0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Confinement of Masonry Columns with the FRCM-System: Theoretical and Experimental Investigation

Autor(en): ORCID
ORCID

ORCID
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Infrastructures, , n. 11, v. 5
Seite(n): 101
DOI: 10.3390/infrastructures5110101
Abstrakt:

Fabric Reinforced Cementitious Matrix (FRCM) systems are promising solutions for the confinement of masonry columns because they demonstrate strengthening effectiveness and, at the same time, compatibility with historical substrates. Nevertheless, the matrix is responsible for the stress-transfer from the structural element to the fabric-reinforcement. Therefore, in the case of poor-quality mortar, the effectiveness of the strengthening can be limited or even compromised. On the other hand, the low content of fibers utilized for FRCM systems generally involves the need to apply more layers in order to accomplish design requirements and a continuous configuration of the reinforcement is more often addressed. Few experimental and theoretical investigations have been targeted to the before mentioned aspects in the recent past, namely the influence of the kind of mortar, the number of layers, and the strengthening configuration (continuous, discontinuous) on the effectiveness of confinement. The present paper refers to the results of an experimental investigation on FRCM confined clay brick masonry. A series of small-scale masonry columns were tested under monotonic centered load until collapse. The varied parameters were the number of confining layers (i.e., 1, 2, and 3) and the confinement configuration (i.e., continuous and discontinuous). The performed research aims to contribute in strengthening to the knowledge in the field of FRCM-confinement, mainly focusing on some of the mentioned unexplored aspects (number of layers, strengthening configuration) that could be considered for validation/improvement of analytical design-oriented formulas. In particular, some analytical models, available in the technical literature, were adopted for predicting the herein reported experimental results. Even if based on few experimental results, the outcomes showed that the number of FRCM-layers and the confinement configuration were crucial parameters affecting the confining effectiveness. The compressive strength was satisfactorily predicted in all cases by the two available utilized models. On the other hand, an improvement in the utilized AOM model is suggested in order to include the stress–strain curves of the hardening type.

Copyright: © 2020 the Authors. Licensee MDPI, Basel, Switzerland.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10723141
  • Veröffentlicht am:
    22.04.2023
  • Geändert am:
    10.05.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine