Component Modeling for Fire Behavior of Shear Tab Connections
Autor(en): |
James A. Gordon
Erica C. Fischer |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Engineering Journal, September 2023, n. 3, v. 60 |
Seite(n): | 129-154 |
DOI: | 10.62913/engj.v60i3.1210 |
Abstrakt: |
During a building fire scenario, the behavior and capacity of gravity connections can significantly contribute to the integrity of steel-framed building structures. Because gravity connections are subjected to axial and flexural force demands and have a limited rotational capacity due to large beam rotations during a fire scenario, a connection model is needed to simulate their behavior when using analytical models to simulate the behavior of a steel structure in fire. This study develops a component model for shear tab connections at ambient and elevated temperatures in the opensource finite element program, OpenSees, to further enable the use of OpenSees for simulating steel structures in fire. Although the developed component model is not limited to implementation within OpenSees. The developed component model is benchmarked against experimental tests of isolated connections and a structural assembly with shear tab connections subjected to mechanical and thermal loads. Through benchmarking, it is shown that (1) the developed component model could be used to simulate connection behavior during a fire scenario and (2) simulating the ductility of connections and connecting components due to damage is critical when simulating the behavior of shear tab connections exposed to fire. |
- Über diese
Datenseite - Reference-ID
10782282 - Veröffentlicht am:
17.05.2024 - Geändert am:
17.05.2024