Most of the deep-water bridges in Chinese reservoirs are concentrated on rivers in the southwest region. The unique structural characteristics of arch bridges are more in line with the geological topography requirements of deep reservoir areas, making them the bridge type of choice for bridges in deep reservoir areas. While the southwest region is an earthquake-prone area, in order to study the safety of arch bridges across deep water in the reservoir area, it is necessary to analyze the effect of water under seismic behavior on the box section arch ring and explore the effect of arch inundation depth on the dynamic response of arch bridges in the reservoir area. In this study, the effect of fluid-solid coupling is considered, the modified Morison equation is used to calculate the hydrodynamic pressure, and the effect of arch bridge inundation depth on the dynamic response is analyzed based on the Midas/civil finite element model of the arch bridge in the Yunnan reservoir area. The results show that the seismic response of the arch bridge across the reservoir is greatly influenced by the submergence depth of the arch bridge due to the fluid-solid coupling effect, and the influence of the hydrodynamic pressure on the longitudinal moment (My) and transverse moment (Mz) of the arch bridge increases with the increase of the submergence depth. There is a threshold value of the submergence depth. When the submergence depth is less than the threshold, the effect of fluid-solid coupling is negligible, and when the submergence depth is greater than the threshold, the fluid-solid coupling effect is significant. The thresholds for different parts of the main arch ring are different. The most unfavorable water depth in different parts of the main arch ring is not necessarily the water depth when the arch ring is completely submerged. Based on this result, for reservoir arch bridges in high intensity areas, it is recommended that the inundation depth of arch bridges crossing deep water reservoirs should be h/f less than or equal to 5/8 f.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1155/2022/3873935.
  • Über diese
    Datenseite
  • Reference-ID
    10776795
  • Veröffentlicht am:
    12.05.2024
  • Geändert am:
    12.05.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine