0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Accuracy of the CM Carbide Method When Testing Counter-Floors Used in the Construction Industry

Autor(en): (Lublin University of Technology , Lublin Poland)
(Lublin University of Technology , Lublin Poland)
(Lublin University of Technology , Lublin Poland)
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Civil and Environmental Engineering Reports, , n. 1, v. 30
Seite(n): 64-73
DOI: 10.2478/ceer-2020-0006
Abstrakt:

Special requirements are placed on finishing materials and foundations for these materials. The technical datasheets for wooden floors contain detailed moisture guidelines regarding counter-floors for these materials. To check the moisture level, the carbide method (CM method) is recommended by manufacturers and many specialists. The authors of the paper performed moisture tests for various counter-floors (anhydrite and cement jointless floors, cement-sand mixtures) using the direct gravimetric (laboratory) method and the carbide method. Test results were collected and analyzed.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.2478/ceer-2020-0006.
  • Über diese
    Datenseite
  • Reference-ID
    10705139
  • Veröffentlicht am:
    19.02.2023
  • Geändert am:
    19.02.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine