0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Real-Time Integration of Identification and Semiactive Optimization Control for Mass Damper-Building Combined Systems under Known/Unknown Seismic Excitations

Author(s): ORCID
ORCID
ORCID
ORCID
Medium: journal article
Language(s): English
Published in: Structural Control and Health Monitoring, , v. 2023
Page(s): 1-16
DOI: 10.1155/2023/6658364
Abstract:

The integration of structural identification and vibration optimal control has been studied. Since the semiactive optimization vibrational control of civil structures needs to be implemented by massive control devices such as mass dampers, it is necessary to investigate the real-time integration of identification and semiactive optimization vibration control for mass damper-building combined systems. However, there is a lack of such studies in the literature. In this paper, a methodology is presented for real-time integration of identification and semiactive optimization vibration control of the mass damper-building combined system under known/unknown seismic excitations. For the combined system under known seismic excitations, the identification is implemented by the extended Kalman filter (EKF) using only partial structural acceleration responses. The identified structural state and parameters of mass damper-building systems are integrated in real time for the optimal control of systems by the linear-quadratic regulator (LQR) control algorithm and the Hrovat semiactive optimization control strategy via semiactive optimization mass dampers (SAMD). Then, it is extended to the scenario of unknown seismic excitations. The partially measured structural acceleration responses are absolute ones in this case, so the generalized extended Kalman filter with unknown input (GEKF-UI) developed by the authors is used to identify the structural input-state parameters of the mass dampers-building combined systems. The identification results are also integrated in real time for the semiactive optimization control of the combined system via SAMD. Two numerical simulation examples are used to test the proposed integration methods. It is shown that the proposed integration methods can reach almost the same optimal control effects as the conventional semiactive optimization control with known parameters of the mass damper-building combined systems under known/unknown seismic excitations.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1155/2023/6658364.
  • About this
    data sheet
  • Reference-ID
    10749409
  • Published on:
    14/01/2024
  • Last updated on:
    14/01/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine