Wirksamkeit örtlicher Bewehrungselemente zur Querkrafttragfähigkeit von Deckenplatten mit integrierten Leitungsführungen

Author(s):

Medium: journal article
Language(s): de 
Published in: Beton- und Stahlbetonbau, , n. 8, v. 106
Page(s): 522-530
DOI: 10.1002/best.201100041
Abstract:

Efficiency of local reinforcing elements for the shear force bearing capacity of floor slabs with integrated service ducts

In building construction, reinforced concrete floors with integrated ducts are increasingly executed. In case of the installation of larger duct cross sections as well as in case of the accumulation of small tubes, the shear force resistance of reinforced concrete floors drops down strongly. In such cases shear reinforcement is required. So far, there have been no design rules for the dimension of local reinforcement in the area of ducting. This often leads to a refusal of such systems. Due to these reasons, the shear force bearing capacity of one-way reinforced concrete floor slabs with different types of ducting were analysed. The experiments demonstrate the increase in shear force bearing capacity of floor slabs with integrated service ducts by the use of local shear reinforcing elements.

Available from: Refer to publisher