Application of the Equivalent Static Analysis procedure for the seismic design of buildings with added viscous dampers

 Application of the Equivalent Static Analysis procedure for the seismic design of buildings with added viscous dampers
Author(s): , , , ORCID, ORCID
Presented at IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016, published in , pp. 1071-1075
DOI: 10.2749/stockholm.2016.1058
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.19 MB

Most of the actual seismic design procedures for structures equipped with viscous dampers requires the development of non-linear time-history analyses, which, even though of quite common use among ...
Read more

Bibliographic Details

Author(s): (Department DICAM, University of Bologna, Italy)
(Department DICAM, University of Bologna, Italy)
(Department DICAM, University of Bologna, Italy)
ORCID (Department DICAM, University of Bologna, Italy)
ORCID (Department DICAM, University of Bologna, Italy)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Published in:
Page(s): 1071-1075 Total no. of pages: 5
Page(s): 1071-1075
Total no. of pages: 5
Year: 2016
DOI: 10.2749/stockholm.2016.1058
Abstract:

Most of the actual seismic design procedures for structures equipped with viscous dampers requires the development of non-linear time-history analyses, which, even though of quite common use among the researchers, still represent a challenge for professional engineers. The paper describes a simple Equivalent Static Analysis procedure for the seismic design of building structures equipped with added viscous damper. The procedure, which is based on the fundamentals of the dynamics of multi-storey frame structures with added viscous dampers, is aimed at estimating the maximum forces in the viscous dampers as well as the peak internal actions in the structural members. The simplified procedure is applied for the design of a 3-storey reference steel frame analysed by other researchers.

Keywords:
design procedure viscous dampers equivalent static analyses